Your browser is not supported. For the best experience, you should upgrade to a modern browser with improved speed and security.

Edison ECSR50 - Dual-Element, Time-Delay Fuse, Class RK5 600Vac, 50A

Checking price...
Decrease quantity
Increase quantity

Your Order Templates
Save products for later, or create lists to quickly re-buy items for routine jobs.

Add to Order Template

Inventory At Nearby Branches



ECSR, Class RK5 600Vac, 1 to 60A, Dual-Element, Time-Delay Fuses

  • Provides motor overload, ground fault and short-circuit protection. When used in circuits subject to surge currents such as those caused by motors, transformers and other inductive components, these fuses can be sized close to full load amps to give maximum overcurrent protection.
  • Permits the use of smaller and less costly switches. The time-delay feature makes it possible to use fuse amp ratings which are much smaller than those of non time-delay fuses. Considerable cost saving occurs by permitting the use of smaller size switches, panels and fuses themselves.
  • Provides a higher degree of short-circuit protection (greater current limitation) in circuits in which surge currents or temporary overloads occur.
  • Helps protect motors against burnout from overloads.
  • Gives motor running back-up protection to motors without extra costs.
  • Helps protect motors against burnout from single phasing on three-phase systems.
  • Simplifies and improves blackout prevention (selective coordination).
  • Dual-element fuses can be applied in circuits subject to temporary motor overloads and surge currents to provide both high-performance, short-circuit and overload protection.
  • The overload element provides protection against low level overcurrent of overloads and will hold an overload which is five times greater than the amp rating of the fuse for a minimum of ten seconds.

Catalog Symbol: ECSR
Dual-Element, Time-Delay - 10 seconds (minimum) at 500% rated current

  • Volts: 600Vac (or less)
  • Amps: 1 to 60A
  • IR: 200kA RMS Sym.
Agency Information: CE, UL Listed, Std. 248-12, Class RK5, Guide JDDZ, File E162363 CSA Certified, HRCI-R C22.2 No. 248.12, Class 1422-02, File 53787


NameEdison ECSR50 - Dual-Element, Time-Delay Fuse, Class RK5 600Vac, 50A
Gemaire Item NumberEDIECSR50
Manufacturer Product NumberECSR50
SKU - PIM Number1407439641431
ERP Number289045
Unit of MeasureEACH
Weight0.3 Pound (lb.)
Length5.5 Inches (in)
Width1.1 Inches (in)
Height1.1 Inches (in)
Hazardous MaterialNo
EPA Cert RequiredNo
Country of OriginMEX
ApplicationAC Power Distribution System Mains, Feeders and Branch Circuits, Protection of Motor and Motor Branch Circuits, Transformers and Other Inductive Loa